03-oct-17 01:05:00 Measurements ended --- . Number of lamps (L) = 7 . Filter running time = 22.25 hours . Total airflow this filter = 2.66 cubic meters . Mean BC concentration of all lamps = 239 ng/vm3 . Report for lamp 1 (370 nm): . Ending voltages: sen(beam) = .785 sen(zero) = 0.021 . ref(beam) = 2.179 ref(zero) = 0.021 . Optical attenuation of filter deposit = 75 . Total aerosol black carbon on filter = 949 ng Mean aerosol black carbon concentration = 357 ng/vm3 --- The reference beam showed lamp intensity fluctuations of 75 ppm. --- Report for lamp 2 (470 nm): . Ending voltages: sen(beam) = .872 sen(zero) = 0.021 . ref(beam) = 2.379 ref(zero) = 0.021 . Optical attenuation of filter deposit = 45 . Total aerosol black carbon on filter = 733 ng Mean aerosol black carbon concentration = 276 ng/vm3 --- The reference beam showed lamp intensity fluctuations of 46 ppm. --- Report for lamp 3 (520 nm): . Ending voltages: sen(beam) = 1.195 sen(zero) = 0.021 . ref(beam) = 1.630 ref(zero) = 0.021 . Optical attenuation of filter deposit = 35 . Total aerosol black carbon on filter = 629 ng Mean aerosol black carbon concentration = 237 ng/vm3 --- The reference beam showed lamp intensity fluctuations of 57 ppm. --- Report for lamp 4 (590 nm): . Ending voltages: sen(beam) = .855 sen(zero) = 0.021 . ref(beam) = 2.114 ref(zero) = 0.021 . Optical attenuation of filter deposit = 29 . Total aerosol black carbon on filter = 588 ng Mean aerosol black carbon concentration = 221 ng/vm3 --- The reference beam showed lamp intensity fluctuations of 203 ppm. --- Report for lamp 5 (660 nm): . Ending voltages: sen(beam) = .360 sen(zero) = 0.021 . ref(beam) = .836 ref(zero) = 0.021 . Optical attenuation of filter deposit = 25 . Total aerosol black carbon on filter = 565 ng Mean aerosol black carbon concentration = 212 ng/vm3 --- The reference beam showed lamp intensity fluctuations of 84 ppm. --- Report for lamp 6 (880 nm): . Ending voltages: sen(beam) = .636 sen(zero) = 0.021 . ref(beam) = 1.056 ref(zero) = 0.021 . Optical attenuation of filter deposit = 16 . Total aerosol black carbon on filter = 505 ng Mean aerosol black carbon concentration = 190 ng/vm3 --- The reference beam showed lamp intensity fluctuations of 118 ppm. --- Report for lamp 7 (950 nm): . Ending voltages: sen(beam) = 1.079 sen(zero) = 0.021 . ref(beam) = 1.092 ref(zero) = 0.021 . Optical attenuation of filter deposit = 14 . Total aerosol black carbon on filter = 474 ng Mean aerosol black carbon concentration = 178 ng/vm3 --- The reference beam showed lamp intensity fluctuations of 126 ppm. --- Disk space = 2.537062E+08 bytes free: One entry at every 10 minutes. There is space for 107868 hours ( 4494 days) more data --- 03-oct-17 01:05:00 Tape feeder mechanism advancing for 2 spot(s). --- ============================================================= --- MAGEE SCIEN. AETHALOMETER --- Aethalometer No. 360 --- 03-oct-17 01:29:54 Measurements started Starting voltages: . sen(zero) = 0.021 ref(zero) = 0.021 . Lamp 1 (370 nm): sen(beam) = 1.768 ref(beam) = 2.171 . Lamp 2 (470 nm): sen(beam) = 1.431 ref(beam) = 2.379 . Lamp 3 (520 nm): sen(beam) = 1.762 ref(beam) = 1.635 . Lamp 4 (590 nm): sen(beam) = 1.136 ref(beam) = 2.044 . Lamp 5 (660 nm): sen(beam) = .468 ref(beam) = .833 . Lamp 6 (880 nm): sen(beam) = .760 ref(beam) = 1.047 . Lamp 7 (950 nm): sen(beam) = 1.258 ref(beam) = 1.083 ---