07-aug-19 15:05:00 Measurements ended --- . Number of lamps (L) = 7 . Filter running time = 15.24 hours . Total airflow this filter = 2.07 cubic meters . Mean BC concentration of all lamps = 386 ng/vm3 . Report for lamp 1 (370 nm): . Ending voltages: sen(beam) = .993 sen(zero) = 0.021 . ref(beam) = 2.393 ref(zero) = 0.021 . Optical attenuation of filter deposit = 75 . Total aerosol black carbon on filter = 953 ng Mean aerosol black carbon concentration = 461 ng/vm3 --- The reference beam showed lamp intensity fluctuations of 148 ppm. --- Report for lamp 2 (470 nm): . Ending voltages: sen(beam) = .925 sen(zero) = 0.021 . ref(beam) = 2.481 ref(zero) = 0.021 . Optical attenuation of filter deposit = 55 . Total aerosol black carbon on filter = 886 ng Mean aerosol black carbon concentration = 428 ng/vm3 --- The reference beam showed lamp intensity fluctuations of 99 ppm. --- Report for lamp 3 (520 nm): . Ending voltages: sen(beam) = 1.355 sen(zero) = 0.021 . ref(beam) = 1.780 ref(zero) = 0.021 . Optical attenuation of filter deposit = 45 . Total aerosol black carbon on filter = 812 ng Mean aerosol black carbon concentration = 392 ng/vm3 --- The reference beam showed lamp intensity fluctuations of 91 ppm. --- Report for lamp 4 (590 nm): . Ending voltages: sen(beam) = .996 sen(zero) = 0.021 . ref(beam) = 2.458 ref(zero) = 0.021 . Optical attenuation of filter deposit = 39 . Total aerosol black carbon on filter = 789 ng Mean aerosol black carbon concentration = 381 ng/vm3 --- The reference beam showed lamp intensity fluctuations of 281 ppm. --- Report for lamp 5 (660 nm): . Ending voltages: sen(beam) = .349 sen(zero) = 0.021 . ref(beam) = .782 ref(zero) = 0.021 . Optical attenuation of filter deposit = 34 . Total aerosol black carbon on filter = 781 ng Mean aerosol black carbon concentration = 377 ng/vm3 --- The reference beam showed lamp intensity fluctuations of 177 ppm. --- Report for lamp 6 (880 nm): . Ending voltages: sen(beam) = .747 sen(zero) = 0.021 . ref(beam) = 1.180 ref(zero) = 0.021 . Optical attenuation of filter deposit = 23 . Total aerosol black carbon on filter = 707 ng Mean aerosol black carbon concentration = 342 ng/vm3 --- The reference beam showed lamp intensity fluctuations of 202 ppm. --- Report for lamp 7 (950 nm): . Ending voltages: sen(beam) = 1.294 sen(zero) = 0.021 . ref(beam) = 1.227 ref(zero) = 0.021 . Optical attenuation of filter deposit = 20 . Total aerosol black carbon on filter = 670 ng Mean aerosol black carbon concentration = 324 ng/vm3 --- The reference beam showed lamp intensity fluctuations of 216 ppm. --- Disk space = 2.541117E+08 bytes free: One entry at every 10 minutes. There is space for 108041 hours ( 4502 days) more data --- 07-aug-19 15:05:00 Tape feeder mechanism advancing for 2 spot(s). --- ============================================================= --- MAGEE SCIEN. AETHALOMETER --- Aethalometer No. 360 --- 07-aug-19 15:29:54 Measurements started Starting voltages: . sen(zero) = 0.021 ref(zero) = 0.021 . Lamp 1 (370 nm): sen(beam) = 2.027 ref(beam) = 2.291 . Lamp 2 (470 nm): sen(beam) = 1.540 ref(beam) = 2.361 . Lamp 3 (520 nm): sen(beam) = 2.060 ref(beam) = 1.736 . Lamp 4 (590 nm): sen(beam) = 1.374 ref(beam) = 2.309 . Lamp 5 (660 nm): sen(beam) = .469 ref(beam) = .739 . Lamp 6 (880 nm): sen(beam) = .903 ref(beam) = 1.145 . Lamp 7 (950 nm): sen(beam) = 1.516 ref(beam) = 1.169 ---