12-jan-17 12:39:55 SERIOUS INSTRUMENT PROBLEM !!! Problem with air flow pump or plumbing. Flow < 1 vLPM. --- 12-jan-17 12:39:55 Measurements ended --- . Number of lamps (L) = 7 . Filter running time = 24.58 hours . Total airflow this filter = 2.61 cubic meters . Mean BC concentration of all lamps = 136 ng/vm3 . Report for lamp 1 (370 nm): . Ending voltages: sen(beam) = .981 sen(zero) = 0.021 . ref(beam) = 2.117 ref(zero) = 0.023 . Optical attenuation of filter deposit = 32 . Total aerosol black carbon on filter = 406 ng Mean aerosol black carbon concentration = 155 ng/vm3 --- The reference beam showed lamp intensity fluctuations of 484 ppm. --- Report for lamp 2 (470 nm): . Ending voltages: sen(beam) = .888 sen(zero) = 0.021 . ref(beam) = 2.422 ref(zero) = 0.023 . Optical attenuation of filter deposit = 24 . Total aerosol black carbon on filter = 398 ng Mean aerosol black carbon concentration = 152 ng/vm3 --- The reference beam showed lamp intensity fluctuations of 377 ppm. --- Report for lamp 3 (520 nm): . Ending voltages: sen(beam) = 1.163 sen(zero) = 0.021 . ref(beam) = 1.661 ref(zero) = 0.023 . Optical attenuation of filter deposit = 20 . Total aerosol black carbon on filter = 363 ng Mean aerosol black carbon concentration = 139 ng/vm3 --- The reference beam showed lamp intensity fluctuations of 433 ppm. --- Report for lamp 4 (590 nm): . Ending voltages: sen(beam) = .775 sen(zero) = 0.021 . ref(beam) = 2.043 ref(zero) = 0.023 . Optical attenuation of filter deposit = 18 . Total aerosol black carbon on filter = 367 ng Mean aerosol black carbon concentration = 140 ng/vm3 --- The reference beam showed lamp intensity fluctuations of 649 ppm. --- Report for lamp 5 (660 nm): . Ending voltages: sen(beam) = .351 sen(zero) = 0.021 . ref(beam) = .932 ref(zero) = 0.023 . Optical attenuation of filter deposit = 15 . Total aerosol black carbon on filter = 349 ng Mean aerosol black carbon concentration = 133 ng/vm3 --- The reference beam showed lamp intensity fluctuations of 531 ppm. --- Report for lamp 6 (880 nm): . Ending voltages: sen(beam) = .557 sen(zero) = 0.021 . ref(beam) = 1.070 ref(zero) = 0.023 . Optical attenuation of filter deposit = 10 . Total aerosol black carbon on filter = 315 ng Mean aerosol black carbon concentration = 120 ng/vm3 --- The reference beam showed lamp intensity fluctuations of 645 ppm. --- Report for lamp 7 (950 nm): . Ending voltages: sen(beam) = .933 sen(zero) = 0.021 . ref(beam) = 1.112 ref(zero) = 0.023 . Optical attenuation of filter deposit = 9 . Total aerosol black carbon on filter = 298 ng Mean aerosol black carbon concentration = 114 ng/vm3 --- The reference beam showed lamp intensity fluctuations of 714 ppm. --- Disk space = 4.855153E+08 bytes free: One entry at every 10 minutes. There is space for 206427 hours ( 8601 days) more data --- Disk space = 4.854333E+08 bytes free: One entry at every 10 minutes. There is space for 206392 hours ( 8600 days) more data --- 12-jan-17 15:22:36 Tape feeder mechanism advancing for 2 spot(s). --- 12-jan-17 15:26:00 ============================================================= Automatic re-start ============================================================= --- MAGEE SCIEN. AETHALOMETER --- Aethalometer No. 360 --- 12-jan-17 15:39:54 Measurements started Starting voltages: . sen(zero) = 0.021 ref(zero) = 0.024 . Lamp 1 (370 nm): sen(beam) = 1.334 ref(beam) = 2.193 . Lamp 2 (470 nm): sen(beam) = 1.143 ref(beam) = 2.550 . Lamp 3 (520 nm): sen(beam) = 1.438 ref(beam) = 1.731 . Lamp 4 (590 nm): sen(beam) = .863 ref(beam) = 1.999 . Lamp 5 (660 nm): sen(beam) = .407 ref(beam) = .972 . Lamp 6 (880 nm): sen(beam) = .612 ref(beam) = 1.086 . Lamp 7 (950 nm): sen(beam) = 1.001 ref(beam) = 1.124 ---