26-jul-18 10:45:00 Measurements ended --- . Number of lamps (L) = 7 . Filter running time = 21.25 hours . Total airflow this filter = 2.19 cubic meters . Mean BC concentration of all lamps = 368 ng/vm3 . Report for lamp 1 (370 nm): . Ending voltages: sen(beam) = .978 sen(zero) = 0.021 . ref(beam) = 2.514 ref(zero) = 0.021 . Optical attenuation of filter deposit = 75 . Total aerosol black carbon on filter = 955 ng Mean aerosol black carbon concentration = 437 ng/vm3 --- The reference beam showed lamp intensity fluctuations of 148 ppm. --- Report for lamp 2 (470 nm): . Ending voltages: sen(beam) = .938 sen(zero) = 0.021 . ref(beam) = 2.654 ref(zero) = 0.021 . Optical attenuation of filter deposit = 56 . Total aerosol black carbon on filter = 906 ng Mean aerosol black carbon concentration = 415 ng/vm3 --- The reference beam showed lamp intensity fluctuations of 81 ppm. --- Report for lamp 3 (520 nm): . Ending voltages: sen(beam) = 1.267 sen(zero) = 0.021 . ref(beam) = 1.821 ref(zero) = 0.021 . Optical attenuation of filter deposit = 46 . Total aerosol black carbon on filter = 832 ng Mean aerosol black carbon concentration = 381 ng/vm3 --- The reference beam showed lamp intensity fluctuations of 94 ppm. --- Report for lamp 4 (590 nm): . Ending voltages: sen(beam) = .919 sen(zero) = 0.021 . ref(beam) = 2.478 ref(zero) = 0.021 . Optical attenuation of filter deposit = 39 . Total aerosol black carbon on filter = 801 ng Mean aerosol black carbon concentration = 366 ng/vm3 --- The reference beam showed lamp intensity fluctuations of 333 ppm. --- Report for lamp 5 (660 nm): . Ending voltages: sen(beam) = .355 sen(zero) = 0.021 . ref(beam) = .859 ref(zero) = 0.021 . Optical attenuation of filter deposit = 34 . Total aerosol black carbon on filter = 785 ng Mean aerosol black carbon concentration = 359 ng/vm3 --- The reference beam showed lamp intensity fluctuations of 160 ppm. --- Report for lamp 6 (880 nm): . Ending voltages: sen(beam) = .716 sen(zero) = 0.021 . ref(beam) = 1.197 ref(zero) = 0.021 . Optical attenuation of filter deposit = 23 . Total aerosol black carbon on filter = 696 ng Mean aerosol black carbon concentration = 318 ng/vm3 --- The reference beam showed lamp intensity fluctuations of 207 ppm. --- Report for lamp 7 (950 nm): . Ending voltages: sen(beam) = 1.240 sen(zero) = 0.021 . ref(beam) = 1.240 ref(zero) = 0.021 . Optical attenuation of filter deposit = 20 . Total aerosol black carbon on filter = 650 ng Mean aerosol black carbon concentration = 297 ng/vm3 --- The reference beam showed lamp intensity fluctuations of 252 ppm. --- Disk space = 2.540708E+08 bytes free: One entry at every 10 minutes. There is space for 108023 hours ( 4501 days) more data --- 26-jul-18 10:45:00 Tape feeder mechanism advancing for 2 spot(s). --- ============================================================= --- MAGEE SCIEN. AETHALOMETER --- Aethalometer No. 360 --- 26-jul-18 11:09:54 Measurements started Starting voltages: . sen(zero) = 0.021 ref(zero) = 0.021 . Lamp 1 (370 nm): sen(beam) = 2.189 ref(beam) = 2.500 . Lamp 2 (470 nm): sen(beam) = 1.742 ref(beam) = 2.665 . Lamp 3 (520 nm): sen(beam) = 2.138 ref(beam) = 1.820 . Lamp 4 (590 nm): sen(beam) = 1.391 ref(beam) = 2.374 . Lamp 5 (660 nm): sen(beam) = .527 ref(beam) = .861 . Lamp 6 (880 nm): sen(beam) = .941 ref(beam) = 1.182 . Lamp 7 (950 nm): sen(beam) = 1.584 ref(beam) = 1.229 ---